Font Size: a A A

Determination Of Nitrosamines In Several Typical Nitrogen-containing Surfactants

Posted on:2020-09-02Degree:MasterType:Thesis
Country:ChinaCandidate:H F GuoFull Text:PDF
GTID:2381330578975873Subject:Applied Chemistry
Abstract/Summary:PDF Full Text Request
The qualitative and quantitative analysis of nitrosamines in nitrogenous surfactants was carried out by using different experimental methods in this thesis.The main research works are outlined as follows:A new qualitative method for N-nitrosamines was established,and two different experimental methods of water-bath decomposition and ultraviolet decomposition were set up.21 kinds of washing samples sold in the market were analyzed by ultraviolet decomposition method,and 13 of them detected to N-nitrosamines.The experimental method is simple,easy to operate,and can be used for qualitative analysis of N-nitrosamines.A method of high performance liquid chromatography-diode array detector(HPLC-DAD)was set up to detect N-nitrosodiethanolamine(NDELA)in cocoic acid monoethanolamide(CMEA)and cocoic acid diethanolamide(CDEA).The wavelength of UV detection was 233 nm,The results showed that at the selected conditions,the N-nitrosodiethanolamine in coconut monoethanolamide and coconut diethanolamide could be qualitatively and quantitatively analyzed.The limit of detection and the limit of quantitation were 15 μg/L,48 μg/L,spiked recovery were 94.5%~98.5%,relative standard deviation(RSD)were 2.6%~7.4%,this method is simple,rapid,and reproducible.It is suitable for the determination of N-nitrosodiethanolamine in general surfactants.A method for the determination of N-nitrosodiethanolamine(NDELA)in coconut oil amide propyl betaine(CAB),coconut diethanolamide(CDEA)and castor oil acylthreonine sodium by high performance liquid chromatography-variable wavelength scanning ultraviolet detector(HPLC-VWD)was established.The wavelength of ultraviolet detection is 234 nm.Under the selected experimental conditions,N-nitrosodiethanolamine in three surfactants can be qualitatively and quantitatively analyzed.The detection limit and quantification limit are 0.6 μg/L and 2 μg/L respectively.The intra-day precision and inter-day precision are 1.2%~2.7% and 1.9%~3.8% respectively.The recovery rate is 88.6%~109.7%.The method is simple,rapid,reproducible and suitable.It is used to detect N-nitrosodiethanolamine in general surfactants.
Keywords/Search Tags:N-nitrosamines, Water-bath decomposition method, Ultraviolet decomposition method, HPLC, Diode array detector, Variable wavelength scanning ultraviolet detector, N-nitrosodiethanolamine
PDF Full Text Request
Related items