Font Size: a A A

Destruction of volatile organic compounds in a dielectric barrier discharge plasma reactor

Posted on:2006-08-12Degree:M.SType:Thesis
University:Oklahoma State UniversityCandidate:Kalpathi, VijayFull Text:PDF
GTID:2451390008461972Subject:Engineering
Abstract/Summary:PDF Full Text Request
Scope and method of study. The purpose of this study was to optimize the operating conditions for the destruction of VOCs in a dielectric barrier discharge plasma reactor. A representative VOC mixture comprising of s-butanol, toluene, methyl isobutyl ketone and butyl acetate was studied to obtain destruction characteristics. The total concentration of VOCs was initially 100 ppm. The operating parameters studied for optimization were primary voltage (60--110 V AC), frequency (200--400 Hz), and relative humidity (0--80%). Initial studies were conducted by varying residence time, keeping the other parameters constant, to determine the effect of residence time on destruction efficiency of VOCs.; Findings and conclusions. The optimum residence time for operation was 0.2 s in the test reactor. A total VOC destruction of 92% was achieved for a primary voltage of 90 V AC (applied voltage across the reactor was 14916 V AC) and frequency of 300 Hz. In general, overall destruction of VOCs increased with an increase in voltage, frequency, and relative humidity. At 90 V primary and 300 Hz, the overall destruction of VOCs was 91% in dry condition and 96% at 35--40% relative humidity. (Abstract shortened by UMI.)...
Keywords/Search Tags:Destruction, Relative humidity, Vocs, Reactor
PDF Full Text Request