Font Size: a A A

Optimization and application of photoluminescence-following electron-transfer with tris(tetramethyl-1,10-phenanthroline) Os/Ru(III) complexes and Fenton based chemiluminescence detection of NSAIDs and dopamine in biological samples

Posted on:2017-03-06Degree:Ph.DType:Dissertation
University:Temple UniversityCandidate:Patel, Mohit PratishFull Text:PDF
GTID:1461390014967515Subject:Chemistry
Abstract/Summary:
Biogenic monoamines such as dopamine play an important role as major neurotransmitters. Simultaneous determination of the concentration changes is thus crucial to understand brain function. Additionally, quantification of pharmaceutically active compounds (PhACs) and their metabolites in biological fluids is an important issue for forensic tests, clinical toxicology and pharmaceutical analysis. We have developed two postcolumn luminescence detection methods coupled to a 2-dimensional-solid phase extraction (2D-SPE) system. The postcolumn reaction methods used in this study are the redox-dependent photoluminescence-following electron-transfer (PFET) and Fenton-based chemiluminescence techniques, for the determination of certain neurotransmitter and nonsteroidal anti-inflammatory drugs (NSAIDs).;A stable [Os(tmphen)3]3+ (tmphen = 3,4,7,8-tetramethyl-1,10-phenanthroline) reagent was prepared in neutral aqueous solution by oxidation of [Os(tmphen)3] 2+ with lead(IV) oxide. [Os(tmphen)3]2+ and [Os(tmphen)3] 3+ are characterized by absorption spectroscopy. [Os(tmphen)3] 3+ stability is compared with [Ru(tmphen)3]3+ in the same pH 7 environment. The properties of Os(III) and Ru(III) complexes were investigated for use as the oxidant in a PFET system. Studies of photophysical and electrochemical properties, the stability of the Os(III) and Ru(III) complexes, and analytical application in PFET detection of oxidizable analytes are presented. The spectroscopic properties of the complexes were not very advantageous, but careful control of the detection system and reaction conditions enabled sensitive detection of the analytes. The method was fully validated and the optimized system was capable of detecting dopamine and acetaminophen at about 30.2 microg L-1 and 33.5 microg L-1, respectively. The limit of detection (LOD) was 1.5 microg L-1 for acetaminophen and 4.3 microg L-1 for dopamine. The accuracy and precision were within bioanalytical method validation limits (90.9 to 101.5 % and RSD < 12.0 %, respectively). Typical analysis time was less than 15 minutes.;Two Fenton-based flow-injection chemiluminescence (CL) methods were developed and validated for the determination of naproxen. Under the optimal experimental conditions the proposed methods exhibited advantages in a larger linear range from 2,760 ng mL-1 to 207,000 ng mL-1 for the first CL method and 41.4 ng mL-1 to 700.0 ng mL-1 for the second CL method. The LOD was 13.8 ng mL-1 for naproxen. The CL mechanisms for the system, H2O2-FeIIEDTA-naproxen was further studied by batch experiments, chemiluminescence spectroscopy, fluorometry, high pressure liquid chromatography (HPLC) and Fourier transform infrared spectroscopy (FTIR). The effects of various interferences commonly found in biological and wastewater systems on the chemiluminescence intensity were also investigated.;We used these methods to determine NSAIDs in commercial pharmaceutical formulations. Another application of these method was for detecting NSAIDs in biological samples. A 2x-1-Dimensional Solid Phase Extraction (2x-1D SPE) method was developed for determination of acetaminophen and naproxen in urine. This method uses both the methanol concentration and the pH advantageously to preferentially isolate analytes of interest from complex sample matrix. These methods were fully validated and had sufficient sensitivity (limit of quantification: acetaminophen; 40.41 mg L-1 - 360.0 mg L -1 and naproxen; 23.03 mg L-1 - 214.8 mg L-1 ) for biological matrices and applications.
Keywords/Search Tags:L-1, Biological, Dopamine, Detection, Application, Iii, Chemiluminescence, Complexes
Related items