Molten Chloride Salts for Heat Transfer in Nuclear Systems

Posted on:2012-11-17Degree:Ph.DType:Dissertation
University:The University of Wisconsin - MadisonCandidate:Ambrosek, James WallaceFull Text:PDF
GTID:1462390011459189Subject:Engineering
Abstract/Summary:PDF Full Text Request
A forced convection loop was designed and constructed to examine the thermal- hydraulic performance of molten KCl-MgCl2 (68-32 at %) salt for use in nuclear co-generation facilities. As part of this research, methods for prediction of the thermo-physical properties of salt mixtures for selection of the coolant salt were studied. In addition, corrosion studies of 10 different alloys were exposed to the KCl-MgCl2 to determine a suitable construction material for the loop.;Using experimental data found in literature for unary and binary salt systems, models were found, or developed to extrapolate the available experimental data to unstudied salt systems. These property models were then used to investigate the thermo-physical properties of the LINO3-NaNO3-KNO 3-Ca(NO3), system used in solar energy applications. Using these models, the density, viscosity, adiabatic compressibility, thermal conductivity, heat capacity, and melting temperatures of higher order systems can be approximated. These models may he applied to other molten salt systems.;Coupons of 10 different alloys were exposed to the chloride salt for 100 hours at 850°C was undertaken to help determine with which alloy to construct the loop. Of the alloys exposed, Haynes 230 had the least amount of weight loss per area. Nickel and Hastelloy N performed best based on maximum depth of attack. Inconel 625 and 718 had a nearly uniform depletion of Cr from the surface of the sample. All other alloys tested had depletion of Cr along the grain boundaries. The Nb in Inconel 625 and 718 changed the way the Cr is depleted in these alloys. Grain-boundary engineering (GBE) of Incoloy 800H improved the corrosion resistance (weight loss and maximum depth of attack) by nearly 50% as compared to the as-received Incoloy 800H sample.;A high temperature pump, thermal flow meter, and pressure differential device was designed, constructed and tested for use in the loop, The heat transfer of the molten chloride salt was found to follow general correlations used to estimate the Nusselt number for water in both the forced convection laminar regime and in the mixed convection regime.
Keywords/Search Tags:Salt, Molten, Systems, Convection, Chloride, Heat, Loop
PDF Full Text Request
Related items