Font Size: a A A

Enthalpy effects on hypervelocity boundary layers

Posted on:1998-05-02Degree:Ph.DType:Dissertation
University:California Institute of TechnologyCandidate:Adam, Philippe HFull Text:PDF
GTID:1462390014474633Subject:Engineering
Abstract/Summary:
Shots with air and carbon dioxide were carried out in the T5 shock tunnel at GALCIT to study enthalpy effects on hypervelocity boundary layers. The model tested was a 1-meter long, 5-deg half-angle cone. It was instrumented with 51 chromel-constantan coaxial thermocouples and the surface heat transfer rate was computed to deduce the state of the boundary layer.; Transitional boundary layers obtained confirm the stabilizing effect of enthalpy. As the reservoir enthalpy is increased, the transition Reynolds number evaluated at the reference conditions increases. This stabilizing effect is more rapid in gases with lower dissociation energy and it seems to level off when no further dissociation can be achieved. Normalizing the reservoir enthalpy with the edge enthalpy appears to collapse the data for all gases onto a single curve. A similar collapse is obtained when normalizing both the transition location and the reservoir enthalpy with the maximum temperature conditions obtained with BLIMPK, a nonequilibrium boundary layer code.; The observation that reference conditions are more appropriate to normalize high enthalpy transition data was taken a step further by comparing the tunnel data with results from a reentry experiment. When the edge conditions are used, the tunnel and flight data are around an order of magnitude apart. This is commonly attributed to high disturbance levels in tunnels that cause the boundary layer to transition early. However, when the reference conditions are used instead, the tunnel and flight data come within striking distance of one another although the trends with enthalpy are reversed. This difference could be due to the cone bending and nose blunting.; Experimental laminar heat transfer levels were compared to numerical results obtained with BLIMPK. Results for air indicate that the reactions are probably in nonequilibrium and that the wall is catalytic. The catalycity is seen to yield higher surface heat transfer rates than the noncatalytic and frozen chemistry models. The results for carbon dioxide, however, are inconclusive. This is, perhaps, because of inadequate modeling of the reactions. Experimentally, an anomalous yet repeatable, rise in the laminar heat transfer level can be seen at medium enthalpies in carbon dioxide boundary layers.
Keywords/Search Tags:Enthalpy, Boundary, Carbon dioxide, Heat transfer, Tunnel
Related items