Font Size: a A A

Vacuum Interrupter Vacuum Testing Research

Posted on:2006-05-18Degree:MasterType:Thesis
Country:ChinaCandidate:J WangFull Text:PDF
GTID:2192360185455647Subject:Electronics and Communications Engineering
Abstract/Summary:PDF Full Text Request
Because of its huge advantages, vacuum breaker is largely applied in the middle voltage domain of power transformer electrical network. Vacuum interrupter, which is the key component of a vacuum breaker, is a passive electronic vacuum device. The primary factor that affects the reliability is the vacuum degree.The insulation strength in vacuum is closely connected with the vacuum degree. So, the vacuum degree in a vacuum interrupter is an important technology index that ensures the vacuum breaker functions of insulation and arc suppressing. If the vacuum degree of the vacuum interrupter, which is used online in a vacuum breaker, is lower than an amount of magnitude, it will lead to the vacuum breaker cannot switch off normally. This will affect and damage to the power transformer system working in order.On the theory of vacuum measurement, with the structure of a vacuum interrupter and the specific characteristic of using a vacuum breaker, vacuum degree on-line measurement in a vacuum interrupter applying the theory of Penning discharge is advanced in this article. First, the vacuum sensor suitable for vacuum degree on-line measurement in the vacuum interrupter is devised by the researches on Panning discharge. Then the vacuum sensor is calibrated, and also the corresponding curve which indicates that the vacuum degree respond to the current of the electric discharge is got. Next, the control mode of on-line measurement is devised for the purpose of on-line measurement in a vacuum interrupter and the concision utility. Also, a system of vacuum degree on-line measurement in a vacuum interrupter is built. Finally, the accuracy of the vacuum degree on-line measurement system is test and verified by the mode of contrast, and the capability of resistance to interference is test by imitated the running condition. The result of experiment is very good.In chapter 1, the background and inducement of vacuum degree on-line measurement in a vacuum interrupter is introduced. The research present situation in our country and abroad is explained, and the advantage and insufficiency of every research way is point out. The importance and feasibility of the study on vacuum degree...
Keywords/Search Tags:vacuum interrupter, Penning discharge, vacuum degree, on-line measurement
PDF Full Text Request
Related items