Font Size: a A A

Eliminate The Development Of The Arc Harmonic Elimination Line Selection Device

Posted on:2007-07-17Degree:MasterType:Thesis
Country:ChinaCandidate:L T QiaoFull Text:PDF
GTID:2192360185982239Subject:Power system and its automation
Abstract/Summary:PDF Full Text Request
The most distribution network and power supply of large industrial-mining enterprises of our country are Non-ground or Peterson-coil-ground system. The Peterson-coil can eliminate the power-frequency electric arc, but the application of Peterson-coil, in one hand make the fault line's selection more difficult; in second hand, with the enlarge of the town and countryside's power network and the addition of the cable, he electric arc is difficult to extinguish. The study of line selection of single phase earth fault, make many progress. But the line selection device base of these fault line selection principle, didn't have the reliability and veracity of apply in the power system.So a new type device which can take the place of Peterson-coil to eleminate arcing fault, and distinguish the single phase fault and ferroresonance fault, then eliminate it. The line selection of this device is high.At the first, the paper analyze the single phase fault and ferroresonance fault. By the alternate electric arc theory, the electric arc will extinguish at the time of the current crossing zero, whether the electric arc can extinguish, is decided by the relationship of medium renew intension Ujf and renew voltage Ufh. When the fault phase's renew voltage raise to a high value, if the Ujf fh, the electric arc will ignite again, this case went on, a steady arcing fault is formed. If we can make the renew voltage don't raise at the set point value, and keep it some time ,while the medium renew intension and dissociate rate raise with time. This can make Ujf >Ufh, then the electric arc will not ignite again, the aim of eliminating the electric arc is reached. With what we said above, we advance some plans that adopt limiting the fault phase voltage raise rate to replace the Peterson-coil: using meatal oxide nolinearity resistance to restrain the renew rate of fault phase voltage to eliminate the electric arc; or earth the fault phase directly, then the arcing fault which is more harm to power system, is changed to metal earth fault.The paper analyze the shadowy earth fault which is caused by PT saturation, and...
Keywords/Search Tags:arcing fault, ferroresonance fault, line selection, uPSD3200
PDF Full Text Request
Related items