Feasibility Study Of Low Dose CT With Ahybrid Iterative Reconstruction Technique For Evaluation Of Airway Stents In Patients With Malignant Tracheal Stenosis

Posted on:2017-11-10Degree:MasterType:Thesis
Country:ChinaCandidate:T T LiFull Text:PDF
GTID:2334330488964974Subject:Medical imaging and nuclear medicine
Abstract/Summary:PDF Full Text Request
ObjectiveTo investigate the image quality of low dose CT with a hybrid iterative reconstruction technique(iDose4, Philips Healthcare) for airway stents evaluation compared to routine dose CT in patients with malignant tracheal stenosis. Methods60 patients(58±8.6 years, 37 male) with airway stent who are randomly assigned into two groups(routine-dose(RD) and low-dose(LD) group, 30 for each) underwent chest CT on a 256-slice CT(RD-group 120 kV, 250 mAs, LD-group 120 kV, 120mAs). Images were reconstructed by filtered back projection(FBP) in RD-group and iDose4 in LD-group. CTDIvol of both groups was recorded. Image quality assessment was performed by two radiologists according to structure demarcation near stents, artifacts, noise, and diagnostic confidence using a five-point scale [1(poor) to 5(excellent)]. Image noise, SNR and CNR were measured. Subjective image quality was compared with Mann-Whitney test. Student t test was used to test objective image quality and radiation dose between groups. ResultsThe score of Sharpness, noise, artifacts, diagnostic confidence about airway stent in LD group were 3.77±0.53, 3.62±0.56, 3.70±0.72, 3.98±0.70, respectively. And the score of Sharpness, noise, artifacts, diagnostic confidence about airway stent in RD group were 3.65±0.69,3.73±0.66,3.35±0.58,3.72±0.67, respectively. There was no significant difference in image quality of structure demarcation, noise and diagnostic confidence between the two groups(P>0.05), while iDose4 enabled a higher score in image quality of artifacts in LD-group compared with those in RD-group(P=0.004). The subjective evaluation scores of image quality from two radiologists indicated excellent inter-observer agreement in scoring results, Kappa value were 0.851,0.847,0.859,0.892,respectively(all P<0.05).The objective noise of LD group(14.7±3.4) was lower and CNR(0.68±0.66) was higher than RD group(SD=15.6 ± 4.5, CNR=0.64 ± 0.51), but were no significant difference(P=0.41, P=0.754, respectively). SNR was significantly higher of LD-group than RD-group(3.76±1.37 VS 3.14±0.90, P=0.044). ConclusioniDose4 improves image quality of low dose CT by comparison of routine dose images reconstructed by FBP, which indicates that iDose4 may help low dose CT to become a routine use for airway stents evaluation.
Keywords/Search Tags:Iterative reconstruction, X-Ray Computed, stents, Radiation Dosage
PDF Full Text Request
Related items