Font Size: a A A

Buckling and Post-Buckling Response of Single Curvature Beam-Columns Under Thermal (Fire) Loads

Posted on:2018-10-03Degree:M.SType:Thesis
University:Southern Illinois University at CarbondaleCandidate:Soltani, Ghulam HussainFull Text:PDF
GTID:2442390002491981Subject:Engineering
Abstract/Summary:
The main objective of this research was to study the buckling and post-buckling response of axially restrained beam-columns under thermal loading. Also the effects of slenderness ratios on pre-buckling and post-buckling behavior which is neglected in AISC specification was examined.;The results of this study indicate that: a) Both the deflection and end moment amplification factors are significantly smaller for the restrained beam-columns subjected to temperature increase than the corresponding unrestrained beam-columns subjected to (mechanical) axial loads. b) The deflection amplification factors tend to decrease with decreasing ratio of end moments. However, reverse seems to occur for the moment amplification factors and as the moment amplification factors tend to increase with decreasing moment ratio particularly in the pre-buckling and the initial post-buckling range (0.1 < T/Tcr < 1.5). c) The thermal amplification factors tend to be smaller than the AISC values even in the pre-buckling range with those for the slender beam-columns significantly smaller than those for the shorter beam-columns.
Keywords/Search Tags:Beam-columns, Post-buckling, Thermal, Amplification factors
Related items