Objective To investigate the suitable injection rate and dose in multislice CT perfusion imaging.Methods Randomized block design was adopted in this study. The treatment factor-contrast medium injection rate was classified into 3, 4, 5, 6 and 8(ml/s); the subjects were divided into 5 blocks grouped by contrast medium injection dose: 0.5, 0.75, 1.0, 1.25 and 1.5(ml/kg) 25 Beagles were randomly enrolled to undergo cerebral CT perfusion imaging. After post processing, time to peak (TIP) and rise value (RV) were measured in superior sagital venous.Results Injection rate had a statistical significant effect on TIP of superior sagital venous. There was no significant difference among group 5, 6 and 8ml/s. Compared with 8ml/s, TTP of superior sagital venous was prolonged when injection rate 3,4 ml/s were adopted. Injection dose had a statistical significant effect on RV of superior sagital venous. There was no significant difference among group 1,1.25 and 1.5ml/kg. Compared with 1..5ml/kg, RV of superior sagital venous was prolonged when injection dose 0.5,0.75 ml/kg were adopted.Conclusion The quality of cerebral CT perfiision imaging was well enough even injection rate as low as 5 ml/s or injection dose as few as 1 ml/kg.
Keywords/Search Tags:Injection rate, Injection dose, Perfusion imaging, Tomography, X-ray computed