The Alpha Spectrometry Method Of Measuring Radon Progeny And Thoron Progeny Concentration By Least Squares Method

Posted on:2019-07-28Degree:MasterType:Thesis
Country:ChinaCandidate:H Y WangFull Text:PDF
GTID:2371330548991635Subject:Nuclear power and nuclear technology engineering
Abstract/Summary:PDF Full Text Request
Radon(222Rn)and thoron(220Rn)belong to radioactive inert gases and are one of the main sources of natural radiation exposure.However,222Rn/220 Rn progeny have a higher dose to humans than 222Rn/220 Rn itself.In the early stage,the project team has established an optimized energy spectrum method for measuring 222Rn/220 Rn progeny,measured the relative parameters of the filter and the energy spectrum apparatus,and realized the rapid and accurate measurement of222Rn/220 Rn progeny within 2 hours.Then by delphi software programming,to achieve any time interval to read spectral data at any energy range function,to achieve fully automated measurment except the sampling process.In order to obtain 222Rn/220 Rn progeny concentration more accurately,in this paper,based on the theoretical formula of optimized energy spectrum method,the concentration counts of 222Rn/220 Rn in multiple time periods were measured and the concentration formulas ofmultiple progeny were established in parallel.The weighted least square method was used to process the data.The concentration matrix of each progeny is obtained by partial derivation of the sum of squared residuals and the concentration of each progeny.The matrix of the relative deviation of each progeny is deduced according to the error formula.The four key parameters of sampling time,total measurement time,measurement count and weighing fator in the error formula of theoretical model are optimized.Through the matlab simulation and optimization,the total alpha and alpha energy spectrum measurements were taken to measure the sampling time and total measurement time of222Rn/220 Rn.For the 222 Rn progeny,the optimized sampling time of the total alpha method was 5 minute and the optimized sampling time of the alpha energy spectrum method was 15 minute.For the 220 Rn progeny,the optimized sampling time of the total alpha and alpha energy spectrum was 30 minute.After the efficiency factor was proposed,the total measurement time was further optimized.For the 222 Rn progeny,the total measurement time optimized of the total alpha method and alpha energy spectrum was 70 minute.For the 220 Rn progeny,the total measurement time optimized of total alpha method and alpha energy spectrum was 170 minute.Through multi-stage recombination experiment,the line chart of the relative deviation accumulation of Ra B,Ra C,Th B and Th C was made,and the optimal measurement counting interval was between 12 and15 segments.The weight factor optimized by experimental research and theoretical analysis is Ni.By comparing different methods,the reliability of 222Rn/220 Rn progeny measured by alpha energy spectrum method was verified.And in the case of low concentrations,alpha energy spectrum multistage method has a smaller relative deviation.Finally,we write the MATLAB-GUI interface program of 222Rn/220 Rn sub-system,which makes data processing easy and reduces the cumbersome manual calculation.In this project,we improved and perfected the original alpha energy spectrum method and obtained the 222Rn/220 Rn concentration more accurately.
Keywords/Search Tags:222Rn/220Rn progeny, alpha spectrum, Multi-stage method, Least square method
PDF Full Text Request
Related items