Abstract/Summary:
In early years of operation, emergency diesel generators have had a minimal rate of demand failures. Emergency diesel generators are designed to operate as a backup when the main source of electricity has been disrupted. As of late, EDGs (emergency diesel generators) have been failing at NPPs (nuclear power plants) around the United States causing either station blackouts or loss of onsite and offsite power. These failures occurred from a specific type called demand failures.;This thesis evaluated the current problem that raised concern in the nuclear industry which was averaging 1 EDG demand failure/year in 1997 to having an excessive event of 4 EDG demand failure year which occurred in 2011. To determine the next occurrence of the extreme event and possible cause to an event of such happening, two analyses were conducted, the statistical and root cause analysis. Considering the statistical analysis in which an extreme event probability approach was applied to determine the next occurrence year of an excessive event as well as, the probability of that excessive event occurring. Using the root cause analysis in which the potential causes of the excessive event occurred by evaluating, the EDG manufacturers, aging, policy changes/ maintenance practices and failure components. The root cause analysis investigated the correlation between demand failure data and historical data.;Final results from the statistical analysis showed expectations of an excessive event occurring in a fixed range of probability and a wider range of probability from the extreme event probability approach. The root-cause analysis of the demand failure data followed historical statistics for the EDG manufacturer, aging and policy changes/ maintenance practices but, indicated a possible cause regarding the excessive event with the failure components.;Conclusions showed the next excessive demand failure year, prediction of the probability and the next occurrence year of such failures, with an acceptable confidence level, was difficult but, it was likely that this type of failure will not be a 100 year event. It was noticeable to see that the majority of the EDG demand failures occurred within the main components as of 2005. The overall analysis of this study provided from percentages, indicated that it would be appropriate to make the statement that the excessive event was caused by the overall age (wear and tear) of the Emergency Diesel Generators in Nuclear Power Plants.;Future Work will be to better determine the return period of the excessive event once the occurrence has happened for a second time by implementing the extreme event probability approach.
Keywords/Search Tags:Emergency diesel generators, Failure, Excessive event, Extreme event probability approach, Nuclear power, Root cause analysis, Year, Occurrence
Related items