The deep tendon reflex is a fundamental aspect of a neurological examination. The two major parameters of the tendon reflex are response and latency, which are presently evaluated qualitatively during a neurological examination. The reflex loop is capable of providing insight for the status and therapy response of both upper and lower motor neuron syndromes. Attempts have been made to ascertain reflex response and latency, however these systems are relatively complex, resource intensive, with issues of consistent and reliable accuracy. The solution presented is a wireless quantified reflex device using tandem three dimensional wireless accelerometers to obtain response based on acceleration waveform amplitude and latency derived from temporal acceleration waveform disparity. Three specific aims have been established for the proposed wireless quantified reflex device: 1. Demonstrate the wireless quantified reflex device is reliably capable of ascertaining quantified reflex response and latency using a quantified input. 2. Evaluate the precision of the device using an artificial reflex system. 3.Conduct a longitudinal study respective of subjects with healthy patellar tendon reflexes, using the wireless quantified reflex evaluation device to obtain quantified reflex response and latency.;Aim 1 has led to the steady evolution of the wireless quantified reflex device from a singular two dimensional wireless accelerometer capable of measuring reflex response to a tandem three dimensional wireless accelerometer capable of reliably measuring reflex response and latency. The hypothesis for aim 1 is that a reflex quantification device can be established for reliably measuring reflex response and latency for the patellar tendon reflex, comprised of an integrated system of wireless three dimensional MEMS accelerometers. Aim 2 further emphasized the reliability of the wireless quantified reflex device by evaluating an artificial reflex system. The hypothesis for aim 2 is that the wireless quantified reflex device can obtain reliable reflex parameters (response and latency) from an artificial reflex device. Aim 3 synthesizes the findings relevant to aim 1 and 2, while applying the wireless accelerometer reflex quantification device to a longitudinal study of healthy patellar tendon reflexes. The hypothesis for aim 3 is that during a longitudinal evaluation of the deep tendon reflex the parameters for reflex response and latency can be measured with a considerable degree of accuracy, reliability, and reproducibility. Enclosed is a detailed description of a wireless quantified reflex device with research findings and potential utility of the system, inclusive of a comprehensive description of tendon reflexes, prior reflex quantification systems, and correlated applications.
Keywords/Search Tags:Reflex, Hypothesis for aim, Neurological examination, System
PDF Full Text Request
Related items