Qingzhen Substation Of 10kV Power Network Neutral Grounding Modes Study

Posted on:2005-08-21Degree:MasterType:Thesis
Country:ChinaCandidate:W Q XuFull Text:PDF
GTID:2132360152965519Subject:Electrical engineering
Abstract/Summary:PDF Full Text Request
The problem about neutral grounding mode of the electric power system is an all-around technical problem which associated with not only power system reliability, insulation coordination, electromagnetic interference, but assault safety.In China, the neutral grounding mode of the 10kV network involved of none grounding, grounding by arc suppressing coils or reactance grounding in the past. With the development of civic power network, low resistance grounding mode was used to restrain the overvoltage, particularly in Guangzhou, Shanghai, Beijing, and Zhuhai etc. It was reported that the overvoltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way. At substations in Guangzhou and Shanghai it was found that the low resistance grounding mode is successful. But in some areas, such as Zhuhai, substations grounding with low resistance revealed some problems, including power supply reliability rapidly dropping, transmitting line often tripping; and person safety being threatened. So interiorly the grounding mode selection of the 10kV network was disputed, which mainly focused on the fault form of 10kV network grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance.This paper studied on how to select the neutral grounding mode of 10kV network. Firstly it analyzed the characteristic of grounding modes about 10kV network. Then with the demonstration of Qingzhen substation of Guizhou province, this paper built a numerical value equivalent model. Taking account of the transformation of the capacitor current or the variety of the grounding point resistance, it calculated the overvoltage level and the grounding point short current value of the net with arc suppressing coil grounding mode or low resistance grounding mode, in addition, the paper discus the problem of electromagnetic interference about the communication. Therefore, the conclusion is valuable to engineering apply, and could be consulted for the selection of the neutral point grounding mode of the 10kV network. As toQingzhen substation of Guizhou province, it is suggested to adopt the arc suppressing coil mode in recent years.
Keywords/Search Tags:10kV electric network, neutral grounding mode, extinction coil, overvoltage
PDF Full Text Request
Related items