Font Size: a A A

Vibrating Analysis About Tow And Connected Piping In The Function Of Wind Load

Posted on:2013-01-11Degree:MasterType:Thesis
Country:ChinaCandidate:C WangFull Text:PDF
GTID:2211330371954598Subject:Power Engineering
Abstract/Summary:PDF Full Text Request
In this paper, the object is tower and connected piping. This paper discusses tower and connected piping's stress and deflection in wind load.First, analysis the connected piping influence the vibration of tower by compared the vibration with the single tower and the tower with connected piping. The results show that the tower equipment with connected piping's vibration is greater than the single tower.Next, consider the single tower and the tower with connected piping's deflection in the wind load. The calculation results show that the tower with connected piping's deflection are greater than the single tower. The influence is related to diameter of piping and tower.Last, consider the tower with connected piping's deflection under wind effect. The analysis results show that the wind speed is fast, then the diameter of the pipeline will obviously influence the tower's deflection. And considering the force where joining the tower and connected piping, and the tower's bottom stress under wind effect. Putting forward the method of the force where joining the tower and connected piping.
Keywords/Search Tags:Tower, Piping, Deflection, The wind load, vibration