Objective:To explore the clinical effect of Minimally invasive percutaneous plateosteosynthesis and Traditional operation to treat fracture of tibial plateau. Methods:Retrospective analysis in January2009to January2012treatment related cases,69cases oftibial plateau fractures were by LISS(28patients) and anatomical plate(41patients).Theincision length,the operative time,blood loss,fracture healing time were observed.Results: All patients were followed up,The excellent and good rate was88.29%in LISSgroup., and75.61%in anatomical plates group, the differences were no statisticallysignificant(P>0.5).The LISS group had shorter incision length,the operative time and lessblood loss than anatomical plates group,and the anatomical plates group,and thedifferences were statistically significant(P<0.5). No differences of the fracture healingtime and postoperative weight-bearing time in two groups were found. Conclusion:Efficacy of tibial plateau factures with plate or anatomical plate is equivalent, but the lessintraoperative tissue damage,shorter operative time,less complication and more conductiveto patient recovery is very obvious in LISS. |