Abstract/Summary:PDF Full Text Request
Objective : To analyze the reasons and influencing factors of titanium plate removal after internal fixation of jaw fracture,and to provide theoretical basis for improving the clinical treatment effect.Methods:To collect the data of 40 cases of itanium plate removal after internal fixation of jaw fracture in our hospital from 2011 to 2015,to summarize the reasons for the removal of titanium plate after operation,and to analyze the influencing factors.Results:The causes of postoperative disassembly : local infection in 18 cases,14 cases were required,titanium plate exposure in 4 cases,1 cases of fracture of titanium plate,titanium plate loosening in 1 cases,local recurrent swelling in1 cases,other 1 cases were removed by other surgery.Conclusion: For the patients with obvious clinical symptom,such as: local discharge,titanium plate exposure,titanium plate fracture,titanium plate loosening,planting needs,relevant operation is needed to remove the titanium plate.For the patients with no obvious symptoms of titanium plate does not advocate surgery to remove.
Keywords/Search Tags:Jaw surgery, Jaw fracture, Rigid internal fixation, Ttanium plate, titanium plate removal