A scanning SQUID microscope for imaging high-frequency magnetic fields

Posted on:2010-12-11Degree:Ph.DType:Thesis
University:University of Maryland, College ParkCandidate:Vlahacos, Constantine PFull Text:PDF
GTID:2442390002975779Subject:Engineering
Abstract/Summary:
This thesis examines the design and operation of a large-bandwidth scanning SQUID microscope for spatially imaging high frequency magnetic fields. Towards this end, I present results on a cryo-cooled 4.2 K scanning SQUID microscope with a bandwidth of dc to 2 GHz and a sensitivity of about 52.4 nT per sample. By using a thin-film hysteretic Nb dc-SQUID and a pulsed sampling technique, rather than a non-hysteretic SQUID and a flux-locked loop, the bandwidth limitation of existing scanning SQUID microscopes is overcome. The microscope allows for non-contact images of time-varying magnetic field to be taken of room-temperature samples with time steps down to 50 ps and spatial resolution ultimately limited by the size of the SQUID to about 10 mum.;The new readout scheme involves repeatedly pulsing the bias current to the dc SQUID while the voltage across the SQUID is monitored. Using a fixed pulse amplitude and applying a fixed dc magnetic flux allows the SQUID to measure the applied magnetic flux with a sampling time set by the pulse length of about 400 ps.;To demonstrate the capabilities of the microscope, I imaged magnetic fields from 0 Hz (static fields) up to 4 GHz. Samples included a magnetic loop, microstrip transmission lines, and microstrip lines with a break in order to identify and isolate electrical opens in circuits.;Finally, I discuss the operation and modeling of the SQUID and how to further increase the bandwidth of the microscope to allow bandwidth of upwards of 10 GHz.
Keywords/Search Tags:Scanning SQUID microscope, Magnetic, Bandwidth
Related items