Font Size: a A A

Medical Populations In Patients With Uterine Fibroids Pulse Diagram And Pulse Diagram

Posted on:2011-06-14Degree:MasterType:Thesis
Country:ChinaCandidate:L J ChangFull Text:PDF
GTID:2204360305472501Subject:Diagnostics of Chinese Medicine
Abstract/Summary:PDF Full Text Request
1 ObjectiveTheoretical Study: To compare the analysis methods of pulse diagnosis analytical instrument and pulse wave analytical instrument, finding the similarities and differences between them. Clinic Research: To study the pulse manifestation, pulse shape, pulse manifestation graph parameters, pulse wave graph parameters, and TCM constitution of uterine fibroids group and non-uterine fibroids group. Getting the characteristics of them and the correlation between the pulse manifestation graph parameters,pulse wave graph parameters and TCM constitution, provide pulse diagnosis reference to TCM constitution conditions for uterine fibroids patients.2 MethodsThe subjects were healthy checking people, collecting samples using case-control principle. Accord to the result of "Questionnaire about constitution of TCM ", define the constitution type of the subjects. Collecting and analyzing the pulse manifestation graph and pulse wave graph, and obtaining the information of the parameters of them. Analyze the data using statistical software.3 Results3.1 Theoretical StudyTo comparing the work principle and analysis method of the two instruments, and finding out the similarities and differences between them. Pulse diagnosis analytical instrument is built on the basis of pulse manifestation, and the parameters related to "Position. Pulse rate. Shape and Situation". On this basis, we evaluate the significance of parameters. The analysis results of pulse manifestation can reflect the overall state of the whole body. Pulse wave analytical instrument is built on the basis of physics and anatomy, from the perspective of cardiovascular function, to determine the significance of analyzing and evaluating the parameters.The analysis results is mainly used to assess the functional status of the circulatory system.3.2 Clinic Research OneTo analyze the parameters'characteristics of pulse manifestation graph and pulse wave graph in uterine fibroids patients.3.2.1 The pulse manifestation distribution characteristics of the uterine fibroids patientsAccording to the name of pulse manifestation which the Pulse diagnosis analytical instrument gives automatically, and there isn't statistically significant about pulse manifestation distribution between the uterine fibroids group and the non-uterine fibroids group, and all kinds of wiry pulse account for more than 70%. The occurrence of weak-wiry pulse in the uterine fibroids group is the highest. But the occurrence of moral wiry pulse and slippery pulse sorts in the uterine fibroids group is higher than in the non-uterine fibroids group; the occurrence of wiry-moderate pulse and hidden pulse in the uterine fibroids group is lower than in the non-uterine fibroids group.3.2.2 The pulse shape distribution characteristics of the uterine fibroids patientsThere is statistically pulse shape significant between the uterine fibroids group and the non-uterine fibroids group. The difference is caused by abc-pulse shape. The occurrence of abc-pulse shape is higher in the uterine fibroids group.3.2.3 The parameters' characteristics of pulse manifestation graph and pulse wave graph in uterine fibroids patientsThere is statistically significant about the parameters of pulse manifestation graph and pulse wave graph between the uterine fibroids group and the non-uterine fibroids group. The mean of h4,Ad,"最佳压力",h4/h1,rAI,rAP is lower in the uterine fibroids group; the mean of h5,h5/h1 is higher in the uterine fibroids group.3.3 Clinic Research twoResearch on the parameters' characteristics of pulse manifestation graph and pulse wave graph in uterine fibroids patients who have the different constitution3.3.1 The constitution and pulse manifestation distribution characteristics of the uterine fibroids group and the non-uterine fibroids groupThere is statistically constitution significant between the uterine fibroids group and the non-uterine fibroids group. The occurrence of phlegm-dampness constitution and excess constitution is higher in the uterine fibroids group. There isn't statistically significant in pulse manifestation distribution between the two groups.3.3.2 The parameters' characteristics of pulse manifestation graph and pulse wave graph in people who have different constitutionThere is statistically significant in the parameters of pulse manifestation graph and pulse wave graph in 9 kinds of constitution. The mean of pulse rate is the highest in special diathesis constitution group, and the Qi depression constitution group's is the lowest. The mean of SBP and CASP is the highest in phlegm-dampness constitution group, and dampness-heat constitution group's is the lowest.There is statistically significant in the parameters' characteristics of pulse manifestation graph and pulse wave graph in gentleness constitution group,deficiency constitution group and excess constitution group. The order of rate mean from the highest to the lowest is deficiency constitution group> excess constitution group> gentleness constitution group. The order of t mean is opposite. The order of DBP mean from the highest to the lowest is gentleness constitution group> excess constitution group> deficiency constitution group. The order of PR mean from the highest to the lowest is deficiency constitution group> gentleness constitution group> excess constitution group. The order of rAI mean and rAP mean from the highest to the lowest is excess constitution group> gentleness constitution group> deficiency constitution group.To compare the parameters of pulse manifestation graph and pulse wave graph in gentleness constitution group and Yang deficiency constitution group. The mean of SBP,DBP,MAP1,MAP2,CASP in gentleness constitution group is higher than in Yang deficiency constitution group. The mean of h4,h5,h5/h1,A/t,PR in gentleness constitution group is lower than in Yang deficiency constitution group.3.3.4 The parameters of pulse manifestation graph and pulse wave graph in people who have the same constitutionTo compare the parameters of pulse manifestation graph and pulse wave graph in people who have the same constitution, we find that there is statistically significant in the parameters' characteristics of pulse manifestation graph or pulse wave graph in gentleness constitution group,Yin deficiency constitution group,Yang deficiency constitution group Qi deficiency constitution group,dampness-heat constitution group and phlegm-dampness constitution group.4 Conclusions(1) The theoretical basis of pulse manifestation graph and pulse wave graph is different, but the main parameters measured are similar. In the case-control study of uterine fibroids, the pulse manifestation graph parameters and pulse wave graph parameters show the same tendency.(2)The pulse manifestation graph parameters h1,h3/hland pulse wave graph parameters PP,rAI of the uterine fibroids patients are lower,and the mean of rAI has statistically significantm in the two groups. The pulse manifestation graph parameters"脉率"and pulse wave graph parameters PR of the uterine fibroids patients group are higher.(3)To compare the pulse shape,the parameters of pulse manifestation graph and pulse wave graph in people, the result shows that the artery flexibility and the artery compliance increased, and the artery peripheral resistance decreased.(4) The excess constitution group is susceptible to have uterine fibroids, especially phlegm-dampness constitution.(5) The mean of pulse rate is the highest in special diathesis constitution group, and deficiency constitution group's pulse rate is faster, especially Qi deficiency.(6) Phlegm-dampness constitution cause SBP, CASP's increase. The deficiency constitution group'systolic function reduce, and vascular compliance increased.(7) To compare the parameters of pulse manifestation graph and pulse wave graph in people who have the same constitution, and we find that the difference is caused by gentleness constitution,Yang deficiency constitution,Qi deficiency constitution,dampness-heat constitution and phlegm-dampness constitution.
Keywords/Search Tags:pulse manifestation graph, pulse wave graph, constitution, check-up population, uterine fibroids
PDF Full Text Request
Related items