Font Size: a A A

Study On Statistical Function Of Automatic Metering Automation System Customer Outage Time

Posted on:2015-04-12Degree:MasterType:Thesis
Country:ChinaCandidate:Y H GaoFull Text:PDF
GTID:2272330452460463Subject:Electrical engineering
Abstract/Summary:PDF Full Text Request
When the power supply enterprise production scheduling, operation Department, lack ofcommunication and coordination, and the power supply departments and the lack of effectivecommunication outage event contact, easy to cause the customer outage time incorrect release,adverse effects. In order to reduce the impact due to statistical methods, different means and10kV line and the corresponding relationship between public transformer brings to customeroutage time statistics, the use of automatic metering station terminal, distribution terminal,load management terminal automatic acquisition function and the main station dataprocessing function, the establishment of automatic acquisition of statistical function ofcustomer outage time measurement automation system based on lifting, customer outage timestatistical automation level and accuracy. For the timely, effective meet customer outage timestatistics, measurement automation system and marketing management information systembased on automatic acquisition function, carries on the research of customer outage time. Apractical level in the theoretical knowledge of current measurement automation technologymatured and automation system function improve constantly, build customer outage timetechnology framework for automatic acquisition function, logic judgment rule summaryapplies to customer outage events, and develop customer outage time automatic acquisitioninquiry function module. Through the operation and application of the pilot of the powersupply enterprise, in the measurement automation system for completion of the actualcustomer outage time data judgment, screening, and related outage information contrastmarketing management information system, the two examination of outage event information,automatic statistics accurately customer outage time, can effectively improve the timeliness ofcustomer outage time statistics, improve customer service quality.Through the introduction of smart grid functional requirements and technical foundation,explains the hardware architecture, measurement automation system function module,communication channel, function. This paper completed the overall design, functionapplication is as follows:(1) power information collection. Power information acquisitionfunction of data acquisition, storage function of the measurement automation system outageinformation.(2) outage information logic.(3) automatic alignment outage information.(4) outage information query.(5) outage information statistics.(6) measurement and theautomation system of marketing management information system interface design. At thecompletion of the overall design function, the customer outage time automatic acquisitiontechnology application in the measurement automation.
Keywords/Search Tags:Customer outage time, Communication protocol, automatic collection, logicaljudgment
PDF Full Text Request
Related items