Font Size: a A A

Experimental Study On Seismic Performance Of Autoclaved Aerated Concrete Masonry Wall

Posted on:2012-05-07Degree:MasterType:Thesis
Country:ChinaCandidate:B W DongFull Text:PDF
GTID:2212330338497658Subject:Structural engineering
Abstract/Summary:PDF Full Text Request
To understand the seismic performance of autoclaved aerated concrete block masonry wall,8 autoclaved aerated concrete block masonry walls were tested under low cycle reversed lateral load. Based on the experiment,cracking and failure modes are observed and load - displacement hysteretic curves are measured. Besides, kinds of seismic indicators such as feature value of load and displacement, ductility factor, Energy dissipation and Stiffness degradation rules are obtained. Test and analysis results show that most of cracks shaped X propagate through the block whose failure mode is shear. Aspect ratio and axial compression also result in some influences to ratio Stiffness and fracture morphology .It can be deduced that as reducing the aspect ratio , increasing the axial compression ratio and enhancing the block strength ,seismic strength and shear strength of wall are enhanced .The seismic performance is not lower than ordinary sinter brick masonry wall from the experiment.
Keywords/Search Tags:masonry structure, anti-seismic performance, low cycle reversed load test, Autoclaved aerated concrete masonry walls, hysteretic curve
PDF Full Text Request